5.3.1.1.5. vlcp.protocol.openflow.defs.openflow13¶
Note
This document is generated from the source file.
/* Copyright (c) 2008 The Board of Trustees of The Leland Stanford * Junior University * Copyright (c) 2011, 2012 Open Networking Foundation * * We are making the OpenFlow specification and associated documentation * (Software) available for public use and benefit with the expectation * that others will use, modify and enhance the Software and contribute * those enhancements back to the community. However, since we would * like to make the Software available for broadest use, with as few * restrictions as possible permission is hereby granted, free of * charge, to any person obtaining a copy of this Software to deal in * the Software under the copyrights without restriction, including * without limitation the rights to use, copy, modify, merge, publish, * distribute, sublicense, and/or sell copies of the Software, and to * permit persons to whom the Software is furnished to do so, subject to * the following conditions: * * The above copyright notice and this permission notice shall be * included in all copies or substantial portions of the Software. * * THE SOFTWARE IS PROVIDED “AS IS”, WITHOUT WARRANTY OF ANY KIND, * EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND * NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS * BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN * ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN * CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE * SOFTWARE. * * The name and trademarks of copyright holder(s) may NOT be used in * advertising or publicity pertaining to the Software or any * derivatives without specific, written prior permission. */ Created on 2015/7/14
author: | hubo |
---|
-
vlcp.protocol.openflow.defs.openflow13.
OFPQ_MAX_RATE_UNCFG
= 65535¶ /* Common description for a queue. */
-
vlcp.protocol.openflow.defs.openflow13.
OFPQ_MIN_RATE_UNCFG
= 65535¶ /* Max rate > 1000 means not configured. */
-
vlcp.protocol.openflow.defs.openflow13.
OFPXMT_OFB_ALL
= 1099511627775¶ - /* The VLAN id is 12-bits, so we can use the entire 16 bits to indicate
- special conditions.
*/
-
vlcp.protocol.openflow.defs.openflow13.
OFP_FLOW_PERMANENT
= 0¶ /* By default, choose a priority in the middle. */
-
vlcp.protocol.openflow.defs.openflow13.
SERIAL_NUM_LEN
= 32¶ - /* Body of reply to OFPMP_DESC request. Each entry is a NULL-terminated
- ASCII string. */
-
vlcp.protocol.openflow.defs.openflow13.
nicira_header
= nicira_header¶ /* Header for Nicira-defined actions. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_experimenter
= ofp_action_experimenter¶ /* ## ———————- ## / / ## OpenFlow Instructions. ## / / ## ———————- ## */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_experimenter_desc
= ofp_action_experimenter_desc¶ /* Actions property */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_group
= ofp_action_group¶ /* Action structure for OFPAT_SET_NW_TTL. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_mpls_ttl
= ofp_action_mpls_ttl¶ /* Action structure for OFPAT_PUSH_VLAN/MPLS/PBB. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_nw_ttl
= ofp_action_nw_ttl¶ /* Action structure for OFPAT_SET_FIELD. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_output
= ofp_action_output¶ /* Action structure for OFPAT_SET_MPLS_TTL. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_pop_mpls
= ofp_action_pop_mpls¶ /* Action structure for OFPAT_GROUP. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_push
= ofp_action_push¶ /* Action structure for OFPAT_POP_MPLS. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_set_field
= ofp_action_set_field¶ - /* Action header for OFPAT_EXPERIMENTER.
- The rest of the body is experimenter-defined. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_type
= ofp_action_type¶ - /* Action header that is common to all actions. The length includes the
- header and any padding used to make the action 64-bit aligned.
- NB: The length of an action must always be a multiple of eight. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_action_type_bitwise
= ofp_action_type_bitwise¶ /* Body of reply to OFPMP_GROUP_FEATURES request. Group features. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_aggregate_stats_reply
= ofp_aggregate_stats_reply¶ - /* Table Feature property types.
- Low order bit cleared indicates a property for a regular Flow Entry.
- Low order bit set indicates a property for the Table-Miss Flow Entry.
*/
-
vlcp.protocol.openflow.defs.openflow13.
ofp_aggregate_stats_request
= ofp_aggregate_stats_request¶ /* Body of reply to OFPMP_AGGREGATE request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_bad_instruction_code
= ofp_bad_instruction_code¶ - /* ofp_error_msg ‘code’ values for OFPET_BAD_MATCH. ‘data’ contains at least
- the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_bad_match_code
= ofp_bad_match_code¶ - /* ofp_error_msg ‘code’ values for OFPET_FLOW_MOD_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_bucket
= ofp_bucket¶ - /* Group types. Values in the range [128, 255] are reserved for experimental
- use. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_bucket_counter
= ofp_bucket_counter¶ /* Body of reply to OFPMP_GROUP request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_buffer_id
= ofp_buffer_id¶ /* Flow setup and teardown (controller -> datapath). */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_capabilities
= ofp_capabilities¶ - /* Current state of the physical port. These are not configurable from
- the controller.
*/
-
vlcp.protocol.openflow.defs.openflow13.
ofp_controller_max_len
= ofp_controller_max_len¶ - /* Action structure for OFPAT_OUTPUT, which sends packets out ‘port’.
- When the ‘port’ is the OFPP_CONTROLLER, ‘max_len’ indicates the max
- number of bytes to send. A ‘max_len’ of zero means no bytes of the
- packet should be sent. A ‘max_len’ of OFPCML_NO_BUFFER means that
- the packet is not buffered and the complete packet is to be sent to
- the controller. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_controller_role
= ofp_controller_role¶ /* Role request and reply message. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_desc_reply
= ofp_desc_reply¶ /* Body for ofp_multipart_request of type OFPMP_FLOW. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_experimenter
= ofp_experimenter¶ /* All ones is used to indicate all queues in a port (for stats retrieval). */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_experimenter_multipart_reply
= ofp_experimenter_multipart_reply¶ /* Experimenter extension. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_flow_mod_failed_code
= ofp_flow_mod_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_GROUP_MOD_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_flow_mod_flags
= ofp_flow_mod_flags¶ /* Special buffer-id to indicate ‘no buffer’ */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_flow_removed
= ofp_flow_removed¶ /* Meter numbering. Flow meters can use any number up to OFPM_MAX. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_flow_removed_reason_bitwise
= ofp_flow_removed_reason_bitwise¶ /* Asynchronous message configuration. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_flow_stats_reply
= ofp_flow_stats_reply¶ /* Body for ofp_multipart_request of type OFPMP_AGGREGATE. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_flow_stats_request
= ofp_flow_stats_request¶ /* Body of reply to OFPMP_FLOW request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_desc_reply
= ofp_group_desc_reply¶ /* Backward compatibility with 1.3.1 - avoid breaking the API. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_desc_stats
= ofp_group_desc¶ /* Group configuration flags */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_features_reply
= ofp_group_features_reply¶ /* Body of OFPMP_METER and OFPMP_METER_CONFIG requests. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_mod
= ofp_group_mod¶ /* Send packet (controller -> datapath). */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_mod_command
= ofp_group_mod_command¶ /* Bucket for use in groups. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_mod_failed_code
= ofp_group_mod_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_PORT_MOD_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_stats_reply
= ofp_group_stats_reply¶ /* Body of reply to OFPMP_GROUP_DESC request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_stats_request
= ofp_group_stats_request¶ /* Used in group stats replies. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_group_type
= ofp_group_type¶ /* Group setup and teardown (controller -> datapath). */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction
= ofp_instruction¶ /* Instruction structure for OFPIT_GOTO_TABLE */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_actions
= ofp_instruction_actions¶ /* Instruction structure for OFPIT_METER */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_experimenter
= ofp_instruction_experimenter¶ - /* Value used in “idle_timeout” and “hard_timeout” to indicate that the entry
- is permanent. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_experimenter_feature
= ofp_instruction_experimenter_feature¶ /* Instructions property */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_goto_table
= ofp_instruction_goto_table¶ /* Instruction structure for OFPIT_WRITE_METADATA */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_meter
= ofp_instruction_meter¶ /* Instruction structure for experimental instructions */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_type
= ofp_instruction_type¶ - /* Instruction header that is common to all instructions. The length includes
- the header and any padding used to make the instruction 64-bit aligned.
- NB: The length of an instruction must always be a multiple of eight. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_instruction_write_metadata
= ofp_instruction_write_metadata¶ /* Instruction structure for OFPIT_WRITE/APPLY/CLEAR_ACTIONS */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_match
= ofp_match¶ - /* Components of a OXM TLV header.
- Those macros are not valid for the experimenter class, macros for the
- experimenter class will depend on the experimenter header used. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band
= ofp_meter_band¶ /* OFPMBT_DROP band - drop packets */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band_drop
= ofp_meter_band_drop¶ /* OFPMBT_DSCP_REMARK band - Remark DSCP in the IP header */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band_dscp_remark
= ofp_meter_band_dscp_remark¶ - /* OFPMBT_EXPERIMENTER band - Experimenter type.
- The rest of the band is experimenter-defined. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band_experimenter
= ofp_meter_band_experimenter¶ /* Meter commands */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band_stats
= ofp_meter_band_stats¶ /* Body of reply to OFPMP_METER request. Meter statistics. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band_type
= ofp_meter_band_type¶ /* Common header for all meter bands */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_band_type_bitwise
= ofp_meter_band_type_bitwise¶ /* Body of reply to OFPMP_METER_FEATURES request. Meter features. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_features_reply
= ofp_meter_features_reply¶ /* Body for ofp_multipart_request/reply of type OFPMP_EXPERIMENTER. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_flags
= ofp_meter_flags¶ /* Meter configuration. OFPT_METER_MOD. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_mod
= ofp_meter_mod¶ - /* ofp_error_msg ‘code’ values for OFPET_BAD_INSTRUCTION. ‘data’ contains at least
- the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_mod_command
= ofp_meter_mod_command¶ /* Meter configuration flags */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_mod_failed_code
= ofp_meter_mod_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_TABLE_FEATURES_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_multipart_request
= ofp_meter_multipart_request¶ /* Statistics for each meter band */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_meter_stats_reply
= ofp_meter_stats_reply¶ /* Body of reply to OFPMP_METER_CONFIG request. Meter configuration. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_multipart_type
= ofp_multipart_type¶ /* Backward compatibility with 1.3.1 - avoid breaking the API. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_oxm
= ofp_oxm¶ - /* Header for OXM experimenter match fields.
- The experimenter class should not use OXM_HEADER() macros for defining
- fields due to this extra header. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_oxm_class
= ofp_oxm_class¶ /* OXM Flow match field types for OpenFlow basic class. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_oxm_header
= ofp_oxm_header¶ /* Bit definitions for IPv6 Extension Header pseudo-field. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_oxm_mask_ipv6
= ofp_oxm_mask_ipv6¶ /* ## —————– ## / / ## OpenFlow Actions. ## / / ## —————– ## */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_packet_out
= ofp_packet_out¶ /* Packet received on port (datapath -> controller). */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_packet_queue
= ofp_packet_queue¶ /* Query for port queue configuration. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_desc_reply
= ofp_port_desc_reply¶ /* Body of OFPMP_GROUP request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_features
= ofp_port_features¶ /* Description of a port */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_mod
= ofp_port_mod¶ /* ## ————————– ## / / ## OpenFlow Extensible Match. ## / / ## ————————– ## */
- /* The match type indicates the match structure (set of fields that compose the
- match) in use. The match type is placed in the type field at the beginning
- of all match structures. The “OpenFlow Extensible Match” type corresponds
- to OXM TLV format described below and must be supported by all OpenFlow
- switches. Extensions that define other match types may be published on the
- ONF wiki. Support for extensions is optional.
*/
/* Fields to match against flows */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_mod_failed_code
= ofp_port_mod_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_TABLE_MOD_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_state
= ofp_port_state¶ /* Features of ports available in a datapath. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_stats_request
= ofp_port_stats_request¶ - /* Body of reply to OFPMP_PORT request. If a counter is unsupported, set
- the field to all ones. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_port_status
= ofp_port_status¶ /* Modify behavior of the physical port */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue
= ofp_queue¶ /* Min rate > 1000 means not configured. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_get_config_reply
= ofp_queue_get_config_reply¶ /* OFPAT_SET_QUEUE action struct: send packets to given queue on port. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_get_config_request
= ofp_queue_get_config_request¶ /* Queue configuration for a given port. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_op_failed_code
= ofp_queue_op_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_SWITCH_CONFIG_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_prop
= ofp_queue_prop¶ /* Min-Rate queue property description. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_prop_experimenter
= ofp_queue_prop_experimenter¶ /* Full description for a queue. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_prop_max_rate
= ofp_queue_prop_max_rate¶ /* Experimenter queue property description. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_prop_min_rate
= ofp_queue_prop_min_rate¶ /* Max-Rate queue property description. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_queue_stats_reply
= ofp_queue_stats_reply¶ - /* Configures the “role” of the sending controller. The default role is:
- Equal (OFPCR_ROLE_EQUAL), which allows the controller access to all
- OpenFlow features. All controllers have equal responsibility.
- The other possible roles are a related pair:
- Master (OFPCR_ROLE_MASTER) is equivalent to Equal, except that there
- may be at most one Master controller at a time: when a controller
- configures itself as Master, any existing Master is demoted to the
- Slave role.
- Slave (OFPCR_ROLE_SLAVE) allows the controller read-only access to
- OpenFlow features. In particular attempts to modify the flow table
- will be rejected with an OFPBRC_EPERM error.
- Slave controllers do not receive OFPT_PACKET_IN or OFPT_FLOW_REMOVED
- messages, but they do receive OFPT_PORT_STATUS messages.
*/
-
vlcp.protocol.openflow.defs.openflow13.
ofp_role_request_failed_code
= ofp_role_request_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_METER_MOD_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_switch_config
= ofp_switch_config¶ /* Configure/Modify behavior of a flow table */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_switch_config_failed_code
= ofp_switch_config_failed_code¶ - /* ofp_error_msg ‘code’ values for OFPET_ROLE_REQUEST_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_switch_features
= ofp_switch_features¶ /* A physical port has changed in the datapath */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_feature_prop_actions
= ofp_table_feature_prop_actions¶ /* Match, Wildcard or Set-Field property */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_feature_prop_experimenter
= ofp_table_feature_prop_experimenter¶ - /* Body for ofp_multipart_request of type OFPMP_TABLE_FEATURES./
- Body of reply to OFPMP_TABLE_FEATURES request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_feature_prop_instructions
= ofp_table_feature_prop_instructions¶ /* Next Tables property */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_feature_prop_oxm
= ofp_table_feature_prop_oxm¶ /* Experimenter table feature property */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_feature_prop_type
= ofp_table_feature_prop_type¶ /* Common header for all Table Feature Properties */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_features_reply
= ofp_table_features_reply¶ /* Body of reply to OFPMP_TABLE request. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_mod
= ofp_table_mod¶ /* Capabilities supported by the datapath. */
-
vlcp.protocol.openflow.defs.openflow13.
ofp_table_mod_failed_code
= ofp_table_mod_failed_code¶ - /* ofp_error msg ‘code’ values for OFPET_QUEUE_OP_FAILED. ‘data’ contains
- at least the first 64 bytes of the failed request */